Place a small amount of sample on the plate, lower the cone, and ensure the gap is set properly.
+-----------------------------------------------------------------------------+ | CAP 2000+ Series | +--------------------------------------+--------------------------------------+ | L-Series | H-Series | | (Low Temp/Visc) | (High Temp/Visc) | +--------------------------------------+--------------------------------------+ | • Temperature: 5°C to 75°C | • Temperature: 50°C to 235°C | | • Ideal for: Paints, inks, | • Ideal for: Asphalt, hot melts, | | coatings, and thin resins | coatings, and polymers | +--------------------------------------+--------------------------------------+
- Manual No. M02-313-I0916
Need to speak to someone? Ametek Brookfield’s technical support team is available Monday–Friday. Reference your instrument’s serial number and the manual revision for fastest service.
By providing a comprehensive guide to the CAP 2000 viscometer, we hope to have provided valuable information to users and potential users of the device. Whether you are a researcher, quality control specialist, or industry professional, the CAP 2000 viscometer is an essential tool that can help you achieve your goals. cap 2000 viscometer manual link
If you need immediate assistance, here are the standard operating instructions found in the manual:
The manual includes critical appendices for long-term instrument health:
With the CAP 2000 warmed to equilibrium, Meera began the test. The dial settled; readings streamed to the connected laptop. When an unexpected fluctuation appeared, she didn’t panic — the manual had shown this exact symptom tied to air bubbles and recommended a slower spindle immersion and a brief degas. She followed the procedure, re-ran the measurement, and obtained smooth, reproducible curves. The data confirmed the sealant’s viscosity profile across temperatures, and the team could confidently move to scale-up.
: The cone, plate, and sample may be extremely hot during or after high-temperature tests; use appropriate safety gear. Reference Links Place a small amount of sample on the
The Brookfield CAP 2000+ Viscometer is an industry-standard cone and plate viscometer. It excels at measuring high-shear viscosity of paints, coatings, resins, and inks. Accessing the official user manual ensures precise calibration, proper cleaning, and accurate measurement techniques. Official Manual Links and Resources
To extend the lifespan of your CAP 2000+ Viscometer and reduce the frequency of factory recalibrations, integrate the following habits derived from the manufacturer's manual into your standard operating procedures:
is distinguished by its variable speed and temperature range capabilities.
Apply a small sample volume (typically less than ) directly onto the center of the plate. Whether you are a researcher, quality control specialist,
Lower the cone, allowing the sample to fill the gap. Start the test. The device will output viscosity in centipoise (
Lower the handle to place the sample on the plate, ensuring no air bubbles are trapped. Do not force the cone onto the plate.
| Issue | Solution | | --- | --- | | Instrument not turning on | Check power cord and ensure proper connection | | Measuring head not aligned | Check cone-and-plate alignment and adjust as needed | | Incorrect viscosity readings | Check instrument calibration and ensure proper sample preparation |
: Match the specific cone spindle size to your expected sample viscosity.
Select the appropriate cone spindle based on expected viscosity and shear rate. The solvent trap must be secured on the shaft.