| Complaint | Possible Cause | Troubleshooting Steps | | :--- | :--- | :--- | | | • Three-way valve stuck in DHW position • Heating circuit sensor (NTC) faulty • Air in the system or pump seized | 1. Check if you are in "summer mode". If so, switch to "winter mode". 2. Bleed any trapped air from your radiators. 3. If the problem persists, the three-way valve, pump, or sensors may need professional replacement. | | No Hot Water, but Heating Works | • Faulty DHW flow sensor/turbine • Plate heat exchanger blocked • Faulty DHW NTC sensor | 1. This is likely a professional issue. The DHW flow sensor is a common failure point. 2. A service technician can diagnose and replace the faulty component. | | Boiler Frequently Turns On and Off | • Boiler is short-cycling due to being oversized for the heating demand • Faulty thermostat • Clogged system water filter or radiator sludge | 1. Check if the room thermostat (if installed) is functioning correctly. 2. Ensure all radiator valves are fully open to allow proper water flow. 3. A technician may need to adjust boiler parameters, clean filters, or power-flush the system. | | Fluctuating Water Temperature | • Faulty DHW NTC sensor • Plate heat exchanger partially blocked with limescale • Inconsistent gas supply pressure | This issue typically requires a professional. A technician will test the sensor, descale or replace the heat exchanger, and check the gas supply. | | Radiators are Not Heating Evenly | • Airlocks in the system • Sludge/debris buildup in radiators • Imbalanced system (need to balance radiator valves) | 1. Bleed all radiators to release trapped air. 2. If some radiators remain cool at the bottom, they may have sludge buildup and require a professional power flush. 3. If the issue persists, a technician can "balance" the system to ensure even heat distribution. | | No Display or Boiler Unresponsive | • No power to the unit • Tripped circuit breaker • Blown internal fuse • Faulty main board | 1. Check your home's electrical panel for a tripped breaker and reset it. 2. Ensure the boiler's main power switch is turned on. 3. This often indicates a need for professional electrical diagnosis. |

Your boiler cannot heat your home or provide hot water if the internal water pressure drops too low.

Need a specific diagram or resistance value for the thermal sensor? Leave a comment on any Lambert owners’ forum, and experienced technicians (many from Poland and Ukraine) will provide the exact measurement – often faster than finding the original instrukcia.

Для максимально ефективної роботи рекомендується встановлювати такі параметри:

: Check the digital display or physical pressure gauge. The central heating system must sit strictly between 1.0 bar and 1.5 bar when cold. Control Panel and Interface Navigation lambert lx 24 fi instrukcia hot

The is a highly efficient, wall-mounted hermetic combi boiler (kombi) designed by the Baymak Heating Systems group to supply both central heating and domestic hot water (DHW). Delivering a maximum thermal output of 24 kW (21,300 kcal/h) alongside an excellent efficiency rating of 93.6% conforming to European 92/42/CEE standards, this dual-heat-exchanger boiler stands out for its compact build, digital user interface, and intelligent fault diagnostics.

: The system lacks sufficient water. Use the filling valve to bring pressure back up to 1.2 bar.

Temperature gauge rises rapidly; steam from radiator cap.

Follow this flow chart if your engine overheats under load: | Complaint | Possible Cause | Troubleshooting Steps

If the unit feels “hot” externally or makes bubbling/kettling sounds:

The Lambert LX 24 Fi is a conventional (non-condensing) hermetic boiler known for its compact footprint and high performance. Heating Power:

Do NOT remove the radiator cap while the engine is hot. Steam burns cause serious injury.

If the boiler’s display or LED indicates “hot” (over 95°C on flow sensor): If the problem persists, the three-way valve, pump,

21,300 Kcal/h (~24 kW) with a 93.6% efficiency rating. Domestic Hot Water (DHW): Provides 13.7 litres per minute.

Adjust these settings to get your shower temp just right, usually between 🚨 Common Error Codes & Fixes

: 21,300 Kcal/h, ideal for medium-sized apartments and houses.

If you only need the wiring diagram or torque specs for the "hot" issue, search for Lambert LX 24 FI workshop manual – it has more technical data than the user instrukcia .

Digital LCD panel for tracking functions and diagnostics. Basic Operation Instructions